This eBook explains how failure analysis helps engineering teams move from visible damage to defensible root cause. Using examples from metallurgical failure analysis, PCB/electronics failure analysis, polymer analysis, and component-level investigations, the guide walks through Covalent’s workflow: defining the problem, gathering service history, starting with non-destructive methods, moving into destructive analysis when needed, and using chemistry and microstructure to complete the story.
Topics include weld porosity, cratering, incomplete penetration, solder non-wetting, plated-through-hole defects, capacitor termination failures, connector contamination, fracture analysis, SEM/EDS, EBSD, micro-CT, SAM, dye-and-pry, cross-sectioning, and polymer FA decision pathways. The eBook emphasizes that effective failure analysis is not just defect hunting—it is a structured, multi-technique investigation that turns physical evidence into practical corrective action.
The failure analysis process in 5 steps
A cracked weld or a joint that won't wet is the symptom, not the cause. A structured investigation gets from the visible damage to a root cause you can defend and fix.
- Define the problem. What failed, how, and what "good" looks like. Keep a known-good part for comparison.
- Gather service history. Lot, process changes, operating conditions and how the part was handled after it failed.
- Start non-destructive. Optical inspection, micro-CT, 2D X-ray and acoustic microscopy (SAM) show cracks, voids and delamination without changing the evidence.
- Go destructive only where needed. Cross-sectioning, dye and pry, and FIB cuts target the exact location the non-destructive steps found.
- Use chemistry and microstructure to finish the story. SEM/EDS, EBSD and surface analysis explain why the defect formed, which points to the corrective action.
Failures covered in the guide
| Area | Examples |
| Metallurgical | Weld porosity, cratering, incomplete penetration, fracture analysis |
| PCB and electronics | Solder non-wetting, plated-through-hole defects, capacitor termination failures |
| Components | Connector contamination |
| Polymers | Decision pathways for polymer failure analysis |
Why order matters
Each destructive step removes evidence. Running non-destructive methods first means the cross-section or FIB cut lands on the real defect the first time.