What Is Thermal Analysis?
Thermal analysis is a group of techniques that measure a property of a material while its temperature is controlled. Depending on the technique, that property is heat flow, mass, dimension, stiffness or surface temperature. Plotting the property against temperature or time shows where the material softens, melts, cures, expands or breaks down.
What thermal analysis can measure:
- Glass transition (Tg), melting and crystallization temperatures
- Enthalpy of melting, curing and other reactions
- Degree of cure and percent crystallinity
- Onset of decomposition, thermal stability and residue
- Filler, polymer and moisture content by mass loss
- Coefficient of thermal expansion (CTE) and softening point
- Storage modulus, loss modulus and tan delta across temperature
- Hotspots and thermal conductivity in devices and thin films
Common uses include setting cure and anneal profiles, checking lot-to-lot consistency, comparing a failed part with a good one, and confirming that a material stays stable across its operating range.
How Thermal Analysis Works
Every project starts with the question you need answered (1): which property matters, which standard applies if any, and what temperatures and atmosphere the part will see in use. We then prepare the sample (2). For DSC and TGA that usually means a few milligrams sealed in a pan. TMA and DMA need a specimen with a defined geometry, and some materials are dried or conditioned before testing.
The instrument then runs a temperature program (3), heating, cooling or holding the sample at set rates in nitrogen, air or another gas. As the program runs, it records a signal (4) such as heat flow, mass or length. Steps, peaks and onsets in that signal mark the glass transition, melting, decomposition or change in expansion. We report the values with the method used and tell you what the results mean for your material or process (5).
Which Thermal Analysis Technique Do You Need?
| If you need to know | Technique | What it measures | Range at Covalent |
|---|---|---|---|
| Tg, melting, crystallinity, cure, heat capacity | DSC | Heat flow into or out of the sample | -90 to 550 °C |
| Decomposition, stability, filler or moisture content | TGA | Mass change | Ambient to 1200 °C |
| CTE, softening point, Tg in solids and films | TMA | Dimension change under a small load | -70 to 400 °C |
| Stiffness and damping across temperature, Tg in composites | DMA | Storage modulus, loss modulus, tan delta | -160 to 600 °C |
| Hotspots and defects in powered devices | IR thermography | Surface temperature map | -25 to 500 °C |
| Thermal conductivity of thin films and interfaces | TDTR | Heat transport after a laser pulse | Thin films on solid substrates |
DSC and TGA are often run together. TGA shows where the sample starts to break down, which sets a safe upper limit for the DSC run. TMA and DMA both measure Tg, but DMA is more sensitive in filled and fiber-reinforced materials. If you aren’t sure which technique fits, tell us what decision you need to make and we’ll recommend one.
Thermal Analysis Standards
We run thermal analysis to recognized test methods or to a method you define. Common standards include:
- DSC: ASTM D3418, ISO 11357, ASTM E1356, ASTM E1269 and ASTM E928
- TGA: ASTM E1131, ISO 11358, ASTM E2550 and ASTM E1641
- TMA: ASTM E831, ASTM E1545, ASTM E2347 and ISO 11359-2
Thermal Testing Applications
| Industry | Typical thermal analysis work |
|---|---|
| Polymers and plastics | Tg, melting point, crystallinity, filler content, oxidative stability |
| Adhesives and coatings | Degree of cure, cure kinetics, Tg after bake |
| Composites | Tg by DMA, resin and fiber content, CTE |
| Semiconductors and electronics | CTE of packaging materials, hotspot mapping, thin-film thermal conductivity |
| Medical devices | Material verification, lot-to-lot comparison, sterilization effects on Tg |
| Batteries and energy | Separator and binder stability, decomposition onset |
Techniques Used in Thermal Analysis
Measures thermal conductivity of thin films and interfaces.