What Do Reverse Engineering Services Include?
Materials reverse engineering answers two questions about an existing product: how is it built, and what is it made of? Covalent's reverse engineering services cover both, so you get structure and chemistry from one lab and one report.
Our work is physical and chemical characterization only: we don't extract software or firmware, or circumvent technical protection measures.
| Type of work | What we measure | Techniques we use |
|---|---|---|
| Structural reverse engineering | Layer stacks, thicknesses, interfaces and internal features, down to the nanometer scale on chips and thin films | Micro-CT, SEM, FIB-SEM, TEM, optical microscopy |
| Chemical reverse engineering (deformulation) | Base polymers, plasticizers, fillers, pigments and additives, with estimated amounts | FTIR, Raman, GC-MS, XPS, NMR, TGA, ICP-MS |
What Is Deformulation?
Deformulation, also called chemical reverse engineering, is the process of taking a finished product apart to identify its ingredients and estimate their amounts. The lab extracts and separates the components, then identifies each one with spectroscopy, chromatography and thermal analysis.
What you get from a reverse engineering project:
- Cross-section images and measurements of layers, interfaces and internal structure
- A list of identified components: base polymers, plasticizers, fillers, pigments, additives and residual solvents
- Approximate amounts for each component, where the methods allow
- Spectra and chromatograms with reference library matches
- A written report and a call with the scientist who ran the work
Why Teams Use Teardowns and Reverse Engineering Services
| Application | What it answers |
|---|---|
| Performance comparisons | Compare the materials and construction of two products to explain why one performs, lasts or fails differently from the other. |
| Bad batches and supplier changes | Compare a good lot with a bad one, or an old supplier's material with a new one, to find what changed. |
| Legacy and obsolete parts | Identify the material in a part that has no drawing or spec sheet, so you can requalify it or find a new source while stock is still available. |
| Specification checks | Confirm that a supplied material or part matches its specification before it goes into production. |
| Patent and trade secret matters | Compositional and structural data that counsel's experts use in patent and trade secret matters, with documented chain of custody. See Legal and IP testing. |
| Unknown residues and contamination | Identify an unknown film, haze, residue or particle found on a part or in a product. See Contamination analysis. |
What We Reverse Engineer
Projects range from chips and device stacks to polymers and the additives, fillers and coatings around them.
- Semiconductor chips and devices
- Electronic components and assemblies
- Metal parts and alloys
- Plastics and polymer compounds
- Coatings, paints and inks
- Adhesives and sealants
- Flexible packaging and multilayer films
- Rubbers and elastomers
- Composites
How a Teardown Project Works
It starts with a scoping call (1), where we review the product, what you already know about it and the questions you need answered, with an NDA on request. We then image and cross-section the structure and use extraction and physical separation to split the materials into fractions (2).
FTIR, Raman and GC-MS identify organic components, NMR resolves molecular structure, and XPS, SEM-EDS and ICP-MS cover surfaces, fillers and elements (3). TGA, ICP-MS and calibrated GC-MS estimate how much of each component is present (4). You get the component list, the data behind it and a call with the scientist who ran the work (5).
ScopeQuestions, NDA, test plan
Tear downCross-sections, extraction
IdentifyFTIR, GC-MS, XPS, SEM-EDS
QuantifyTGA, ICP-MS, GC-MS
ReportData, report, review callTeardown and Deformulation Techniques
No single instrument identifies everything in a product. We combine methods based on what the product is and what you need to learn.
| Technique | What it tells you |
|---|---|
| Micro-CT | Internal 3D structure, voids and assembly details without cutting the part |
| FIB-SEM and TEM | Site-specific cross-sections of chips, devices and thin films, with layer thickness down to the nanometer |
| FTIR | Polymer type, functional groups and many common additives |
| Raman | Polymers, pigments, fillers and crystalline forms, including through some packaging |
| GC-MS | Volatile and semi-volatile organics such as plasticizers, solvents and small-molecule additives |
| ICP-MS / ICP-OES | Elements and metals down to trace levels: catalysts, fillers, pigments |
| XPS | Surface chemistry: coatings, release agents, slip and antistatic additives |
| NMR | Molecular structure of polymers, resins and additives |
| TGA | Polymer, filler and volatile content by weight |
| DSC | Melting point, glass transition and the polymers in a blend |
| XRD | Crystalline fillers, minerals and phases |
| SEM-EDS | Layer structure, particle shape and elemental makeup |
Need HPLC, LC-MS, GPC or ToF-SIMS? We can coordinate those through our Covalent Connect partner labs. Any subcontracted work is disclosed in your quote.
Why Companies Choose Covalent for Product Teardowns
We take products apart and analyze them in our Sunnyvale lab. Cross-sectioning with FIB-SEM, TEM and micro-CT, and chemical analysis with FTIR, GC-MS and XPS, happen under one roof, so samples don't travel between labs and you get one report. The scientist who runs your samples scopes the work with you and walks you through the results. For methods we don't run in-house, we can place work through Covalent Connect, our network of trusted partner labs, and disclose it in your quote.
We sign NDAs before you send samples, and project data is kept in SOC 2 compliant software restricted to your project team. Your deliverables and identifiable project data remain yours; see our Terms.
Turnaround is typically 5–7 business days, with rush options available at an extra cost.
Frequently Asked Questions
What is the difference between reverse engineering and deformulation?
Do you provide CAD models or 3D scans?
Can you tell me the exact amount of every ingredient?
How much sample do you need?
How long does a teardown or deformulation project take?
How do you protect my samples, data and IP?
Can I have any product analyzed?
Can you run reverse engineering or deformulation for a patent or trade secret matter?
Have a Product You Need to Understand?
Describe the product and your questions, and a scientist will recommend a test plan with a quote.