Micro-CT (X-ray Computed Tomography) Analysis

Micro-CT is a non-contact, non-destructive technique that delivers detailed 2D and 3D images of a sample's inside, with sub-micron detail. Covalent runs the Waygate Technologies V|tome|x M Neo in house, with microfocus and nanofocus X-ray tubes and room for parts up to 700 mm tall and 75 kg, alongside our Nordson Dage Quadra 7 for fast 2D and oblique X-ray inspection.

What Is X-ray Computed Tomography?

Micro-CT is a non-destructive method of visualizing and characterizing internal 3D structures of objects. It is capable of high-resolution X-ray reconstructions and allows for better understanding of the interior and exterior of a sample.

High-energy X-rays pass through slowly rotating samples about the X-ray source and the transmitted X-rays are projected onto a detector. This creates 2D X-ray images of the sample at various rotation angles. These 2D X-ray images are then compiled and reconstructed into a 3D model.

Non‑Invasive Biological Imaging

Visualizes internal structures of biological samples without damaging or altering them.

High-Resolution Imaging

Non-destructive 2D/3D visualization of electronic components, battery layers, and hidden defects at sub-micron detail.

Structural and Material Insights

Reveals density differences, porosity, and internal variations in composites and complex materials.

Why Use Micro-CT?

  • Micro-CT is a non-destructive method of visualizing and characterizing internal 3D structures of objects without damaging the sample.
  • It can be used in place of mechanical cross-sectioning when samples cannot be destroyed.
  • Common uses of Micro-CT are in failure analysis of materials that can range from electronics to batteries to even plastics.
  • Beneficial in semiconductor, battery, aerospace and additive manufacturing industries.
  • Beneficial for materials science industries.
  • Micro-CT is also beneficial for biomedical industries.

Non‑Destructive Visualization

Reveals internal structures, defects, and layer measurements without cutting or damaging the sample.

Failure Analysis and Quality Control

Detects cracks, voids, shorting, and manufacturing defects across electronics, batteries, plastics, and composites.

Broad Industry Relevance

Trusted in semiconductors, batteries, biomedical, and materials science where precision imaging drives reliability.

How Micro-CT Works

An X-ray tube produces a cone-shaped beam at up to 300 kV (1). The sample sits on a rotation stage between the source and the detector and turns through 360° (2). As the X-rays pass through it, dense or thick regions absorb more and light regions absorb less, and a flat-panel detector records the transmitted X-rays (3). The system captures a 2D projection at each small step of rotation, often thousands per scan (4). Reconstruction software combines the projections into a 3D volume that you can slice in any direction, measure, and compare with a CAD model (5).

Moving the sample closer to the source magnifies it, so smaller samples reach finer detail. Larger parts are scanned at coarser resolution, or with an offset scan to fit parts up to 500 mm in diameter.

Diagram of micro-CT: an X-ray source up to 300 kV shines a cone beam through a sample on a rotation stage onto a flat-panel detector, the 2D projections from each angle are collected, and a computer reconstructs them into a 3D model with virtual slices
How micro-CT works: X-rays pass through a rotating sample, a detector records a 2D image at each angle, and software reconstructs the images into a 3D model.

Equipment Used for Micro-CT

Waygate Technologies V|tome|x M Neo micro-CT scanner used for 3D X-ray computed tomography at Covalent

Waygate Technologies V|tome|x M Neo

  • 300 kV microfocus and 180 kV nanofocus X-ray tubes.
  • Sub-micron detail detectability.
  • Voxel size: 2 µm (microfocus) down to <0.5 µm (nanofocus).
  • 16 MP Dynamic 41|100 detector, up to 30 fps.
  • Variable focus-detector distance.
  • Max sample size: 310 mm Ø × 700 mm (500 mm Ø with offset scan).
  • Max sample weight: 75 kg.
  • Dimensioning and CAD comparison (VG Studio Max).

Key Differentiators

Micro-CT gives unique structural insight without destroying the sample, but resolution and scan time depend on size and material.

Strengths

  • Shows a part's internal and external structure without cutting it, so the same sample can be scanned, measured and sent on for cross-section or SEM.
  • With the V|tome|x M Neo we resolve sub-micron features and scan whole parts up to 700 mm tall in one setup.

Limitations

  • Resolution scales with sample size: the finest voxel sizes need small samples, and large parts scan coarser.
  • Scans take from 5 minutes to 8 hours depending on size and image quality. Dense metals can cause streak artifacts, which we reduce with beam filtering and scan optimization.

Example Output

2D and 3D Micro-CT scan of a smartwatch

Sample Requirements

We accept samples that are solid or can be securely held in place with hot glue or a fixture to minimize vibrations during measurement. All samples must be stable in atmospheric conditions. No slicing, coating or vacuum treatment is needed.

For 3D CT on the V|tome|x M Neo, samples can be up to 310 mm in diameter (500 mm with an offset scan), 700 mm tall and 75 kg (165 lb). For 2D inspection, the Nordson Dage Quadra 7 offers a 20 × 17.5 in inspection area.

Micro-CT Applications by Industry

Semiconductor

Detects fatigue cracks, head-in-pillow defects, solder voids, wire sweep and shorting in packages, PCBs and full modules. Supports process validation and reliability studies.

Battery

Visualizes electrode layers, overhang, internal shorting and voids in cylindrical, prismatic and pouch cells. Enables thickness and alignment measurements without opening the cell.

Biomedical

Non-destructive imaging of implants, devices and biological samples to reveal internal structures, contamination, or porosity. Ensures compliance, quality, and reliability.

Aerospace and Additive Manufacturing

Reveals voids, lack of fusion and internal geometry in AM parts, castings and composites, and compares the scan to your CAD model.

Geology and Materials Science

Visualizes pore networks, inclusions and fiber orientation in rock cores, composites and foams.

Techniques That Complement Micro-CT

Quick overview method for detecting cracks, voids, and density variations. Complements Micro‑CT’s high‑resolution 3D reconstructions.
Add to Quote
Reveals internal structures through physical sectioning. When paired with Micro‑CT, it provides direct validation of non‑destructive imaging.
Add to Quote
Delivers high‑resolution imaging of exposed cross‑sections for detailed surface and defect analysis beyond CT limits.
Add to Quote

Micro-CT Testing Services at Covalent

Our expert team at Covalent can help better visualize materials using Micro-CT with optimized conditions to better interpret the inner workings of materials. With the V|tome|x M Neo and Nordson Dage Quadra 7 in our Sunnyvale lab, 2D inspection, sub-micron CT and large-part CT all run in house, so your samples stay with us and results come back faster. Our mission is to level the playing field and ensure that clients of all sizes have access to data generated accurately.

Frequently Asked Questions

What types of materials or parts can be scanned with Micro-CT

Samples need to be solid or able to be held in place with hot glue so as to limit vibrations during measurement.

What are the main business applications of Micro-CT?

Micro-CT is often used as a non-destructive visualization method to look at internal features or detect potential failures within a sample.

What size samples can be scanned?

Samples can be up to 5cm maximum in either x, y, and z parameters. Larger samples can be either used in the HX130 (at lower resolution) or sent out to partner labs that can accommodate larger/denser samples.

How accurate are the measurements from Micro-CT scans?

Currently, measurements have an error of 3%.

How long does a typical Micro-CT scan take?

A typical Micro-CT scan takes 2-3 hours. Depending on the resolution needs, the scans can be taken for shorter periods of time, which will decrease the resolution or longer periods of time, which will increase the resolution.

What kind of analysis or reporting is provided after scanning?

A free viewer is provided where clients can have access to the full 3D reconstruction and allows them to go slice by slice through their scanned material. A report is also provided, which can include any failures found or measurements that the client requested.

What is the smallest feature you can see?

The V|tome|x M Neo detects sub-micron features. Voxel size goes down to 2 µm with the microfocus tube and under 0.5 µm with the nanofocus tube, depending on sample size and material.

Can you compare a CT scan to my CAD model?

Yes. We use VG Studio Max with coordinate measurement to dimension parts and compare the scan to your CAD model.