What is Plasma FIB-SEM?
Plasma FIB-SEM combines a high-resolution scanning electron microscope with a focused ion beam generated from an inductively coupled plasma (ICP) source instead of a gallium liquid-metal source. The plasma source delivers far higher usable beam currents while keeping a well-defined probe, so material can be removed at a precise site from volumes hundreds of microns across. Large cross-sections, deep trenches, chunks and 3D volumes that would take a gallium FIB many hours or days to mill become practical.
The Helios 5 Hydra goes one step further. Its plasma source can run four ion species (xenon, argon, oxygen and nitrogen) and switch between them in under ten minutes. Xenon, the heaviest, is the workhorse for fast bulk removal. Argon suits low-energy final polishing and cleaning. Oxygen reacts with carbon-based materials, which makes it useful for cross-sectioning polymers and other organics. Nitrogen is available for specialized reactive milling and surface modification.
Because no gallium is used, there is no gallium implantation, no gallium-induced embrittlement or phase change in sensitive materials such as aluminum alloys, and no gallium signal to confuse downstream EDS, TEM or SIMS analysis. In practice, PFIB closes the gap between the femtosecond laser, which removes bulk material at the millimeter scale, and gallium FIB, which polishes at the nanometer scale.
Large-Volume, Site-Specific Milling
Plasma ion currents up to the microamp range expose cross-sections and volumes hundreds of microns across at a precise site of interest.
Four Ion Species, One Tool
Choose xenon, argon, oxygen or nitrogen to match the material and the step: bulk removal, low-damage polishing or reactive milling of organics.
Gallium-Free Preparation
Inert and reactive gas ions avoid gallium implantation and gallium-induced artifacts in metals, semiconductors and alloys.
Why Use Plasma FIB-SEM?
Many questions sit at a length scale that is too large for gallium FIB and too small or too site-specific for mechanical polishing: a solder joint inside a package, a through-silicon via, a crack beneath a coating, or a representative volume of a battery electrode. PFIB reaches those features directly, at a known coordinate, and then lets you image, map and section them in the same chamber with the electron beam.
Choosing the ion species adds a second lever. The same instrument can rough out a large trench with xenon, polish a TEM lamella with low-energy argon, or cut a clean cross-section through a polymer with oxygen. That reduces the artifacts that come from forcing one ion beam to do every job.
Hours, Not Days
High-current plasma milling cuts large cross-sections and deep trenches far faster than a gallium FIB, with automated workflows for unattended runs.
The Right Ion for the Material
Matching the ion species to the sample chemistry helps reduce curtaining, amorphization and beam damage on difficult materials such as polymers, composites and multilayer stacks.
Prep and Analysis in One Chamber
Ultra-high-resolution SEM imaging, EDS mapping and 3D slice-and-view all run without moving the sample.
How Plasma FIB-SEM Works
The sample is loaded on a five-axis stage, and the SEM locates the site of interest. Gas injection deposits a protective platinum, tungsten, carbon or insulator layer over the site before milling begins (1). In the Hydra’s ion column, xenon, argon, oxygen or nitrogen gas is ionized in an inductively coupled plasma. The ions are extracted, accelerated to between 0.5 and 30 kV, and focused onto the sample by a differentially pumped, triple-lens column. At high current, up to the microamp range, the beam sputters away bulk material along a programmed pattern (2).
The electron column sits at 52° to the ion column, and both beams meet at the same point, so the SEM images the cut face while it is being milled. Lower currents, down to about 1 pA, and low-energy argon then polish the face without changing tools (3). Once the site is exposed, the electron beam takes over for sub-nanometer SEM imaging, EDS elemental mapping, or automated slice-and-view to reconstruct a 3D volume. A nanomanipulator lifts out chunks and lamellae for TEM analysis (4).
Equipment Used for Plasma FIB-SEM
Thermo Scientific Helios 5 Hydra UX DualBeam
- Multi-ion inductively coupled plasma FIB with xenon, argon, oxygen and nitrogen beams, switchable in under 10 minutes
- Ion beam from 500 V to 30 kV and 1 pA to 2.5 µA, for both bulk removal and fine polishing
- Elstar UC+ monochromated SEM column with 0.6 nm resolution at 2 to 15 keV and 1.0 nm at 500 eV
- Oxford Instruments Ultim Max Infinity 100 EDS with AZtecLive Expert for elemental mapping
- AutoTEM 5, Auto Slice & View 5 and Maps 3 for automated lamella prep, 3D tomography and correlative workflows
- CleanConnect inert-gas transfer for air-sensitive samples such as battery materials
Key differentiators
Strengths
- Microamp-range plasma currents remove large volumes far faster than gallium FIB
- Four switchable ion species (Xe, Ar, O and N) match the ion beam to the material and the preparation step
- Gallium-free: no Ga implantation, no Ga-induced embrittlement, and no Ga signal in downstream EDS, APT or SIMS
- Low-energy argon polishing for thin, low-damage TEM lamellae
- Oxygen ion milling for cleaner cross-sections of polymers and other carbon-based materials
- Integrated EDS and automated 3D slice-and-view in the same chamber
Limitations
- Ion-beam imaging resolution is coarser than a gallium FIB, so gallium FIB may still be preferred for final milling of the smallest features
- High-current milling of heterogeneous materials can cause curtaining that needs rocking-polish, spin-mill or protective-cap strategies
- Reactive ions (O and N) chemically modify some materials and must be chosen deliberately
- Like all FIB techniques, it is destructive at the milled site and works best when guided by prior nondestructive localization (X-ray, thermal or electrical)
Samples requirements
Success depends on the material, the depth and size of the region of interest, and the analysis that follows. We can help with sample selection, localization and prep planning.
- Solid-phase, vacuum-stable samples: metals, semiconductors, ceramics, polymers, composites, and biological or organic materials after appropriate preparation
- Conductive or insulating samples; insulators can be coated on site or milled with charge neutralization
- Air-sensitive samples can be loaded by inert-gas transfer (CleanConnect: max. 25 mm diameter, 15 mm height)
Plasma FIB-SEM Applications by Industry
Advanced Packaging Failure Analysis
Cross-section solder bumps, hybrid bonds, TSVs and redistribution layers at a localized fault site, at depths beyond practical gallium FIB reach. See failure analysis.
Gallium-Free TEM Lamella Preparation
Prepare lamellae with xenon and finish with low-energy argon to minimize amorphous damage and avoid gallium contamination for high-resolution and quantitative STEM.
Large-Volume 3D Tomography
Automated slice-and-view with SEM imaging across volumes far larger than gallium FIB can practically section.
Battery and Energy Materials
Cross-section electrodes, separators and solid-state cells, with inert transfer for air-sensitive materials. See energy and battery materials testing.
Polymers, Composites and Organics
Oxygen ion milling gives cleaner cross-sections of carbon-based materials that smear or curtain under noble-gas ions. See polymer and plastic analysis.
Micromechanical Test Specimens
Mill pillars, cantilevers and tensile specimens from bulk materials without gallium-induced embrittlement.
Laser-to-PFIB Correlative Workflows
Rough out a site with the femtosecond laser, then finish with PFIB, bridging millimeter-scale removal and nanometer-scale precision.
Techniques That Complement Plasma FIB-SEM
Millimeter-scale bulk removal ahead of plasma FIB finishing.
Gallium FIB milling for the finest, site-specific work.
Atomic-resolution imaging, EDS and EELS on lamellae finished with low-energy argon.
Nondestructive localization of buried features to target PFIB milling.
Electrical fault localization in XY and depth before physical cross-sectioning.
Electrical characterization of structures exposed by delayering or cross-sectioning.
Mechanical testing of PFIB-machined pillars, cantilevers and micro-specimens.
Plasma FIB-SEM Testing Services at Covalent
Covalent runs the Helios 5 Hydra UX in our Sunnyvale lab alongside our femtosecond laser, gallium FIB-SEM, TEM, micro-CT, thermography and nanoprobing. A sample can go from localization to cross-section to atomic-scale analysis in one coordinated workflow, with experienced FIB scientists choosing the ion species and recipe for each material. Every report includes annotated images, measurements and a scientist’s summary of what the data shows. When a project needs a technique we do not run in-house, we can source it through Covalent Connect, our network of trusted partner labs.
Turnaround is typically 5–7 business days, with rush options available at an extra cost.
Frequently Asked Questions
What does PFIB stand for?
PFIB stands for plasma focused ion beam. A PFIB-SEM pairs a plasma ion column with a scanning electron microscope in one instrument, so you can mill a site and image it in the same chamber.
What is the difference between plasma FIB and gallium FIB?
A gallium FIB uses a liquid-metal ion source and excels at fine, nanometer-scale milling. A plasma FIB uses a gas-based plasma source that supports much higher beam currents, so it removes large volumes far faster, and it introduces no gallium into the sample. Many workflows use both: PFIB for large-volume work and gallium FIB where the finest milling is required.
Why does having multiple ion species matter?
Different materials and steps benefit from different ions. Xenon removes material fastest, argon suits low-energy polishing, and oxygen reacts with carbon-based materials for cleaner cuts in polymers and organics. Switching in under ten minutes lets us match the beam to the sample.
Can PFIB prepare TEM samples?
Yes. The Hydra prepares lamellae by lift-out, and low-energy argon finishing helps minimize surface damage, without the gallium implantation associated with gallium FIB preparation.
How large a cross-section can you make?
PFIB routinely produces cross-sections and volumes hundreds of microns across. For millimeter-scale features, we often combine femtosecond laser bulk removal with PFIB finishing. We’ll recommend an approach during scoping.
Can you handle air-sensitive samples?
Yes. Samples such as battery materials can be transferred into the microscope under inert gas using the CleanConnect system.
How much does plasma FIB-SEM analysis cost?
Cost depends on the size and depth of the region of interest, the number of sites and the analysis that follows. Contact us with your samples and goals for a quote.
How long does plasma FIB-SEM analysis take?
Turnaround is typically 5–7 business days, with rush options available at an extra cost.